Sign In | Join Free | My portofva.com
China ShenzhenYijiajie Electronic Co., Ltd. logo
ShenzhenYijiajie Electronic Co., Ltd.
The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates
Verified Supplier

3 Years

Home > Oxygen Gas Sensor >

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

Brand Name : CITY

Model Number : MOX-3 MOX3 AA829-M10

Place of Origin : Britain

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 2200

Delivery Time : 3 days

Packaging Details : canning

Temperature Compensation : <2% O2 equivalent (0°C to 40°C)

External Load Resistor : 10 kΩ minimum

Housing Material : White ABS

Weight : 42 g

Contact Now

Product Description:

MOX-3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor

Features:

The purpose of this document is to present the performance specification of the MOX3 oxygen gas sensor.

This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).

The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.

Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

Important Note: Connection should be made via recommended mating parts only. Soldering to the sensor will damage it and invalidate the warranty.

For further information on the external load resistance and connection to the recommended mating part, please see Operating Principle OP-04 or contact City Technology.

All performance data is based on measurements made with cylinder gases using a flow rate of 100 mls/min. Conditions at 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, contact City Technology.

Performance characteristics outline the performance of sensors supplied within the first 3 months. Output signal can drift below the lower limit over time.

Specifications:

Measurement range 0 mBar to 1500 mBar O2
Response Time (T90) <15 s (air to 100% O2)
Baseline Offset <200 μV
Linearity Linear 0% to 100% O2

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor


Product Tags:

Medical Oxygen Battery Oxygen Sensor

      

YJJ MOX-3 Oxygen Sensor

      

MOX3 AA829-M10 Oxygen Sensor

      
China YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor wholesale

YJJ MOX-3 MOX3 AA829-M10 Respirator Medical Oxygen Battery Oxygen Sensor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)